H-Index
32
Scimago Lab
powered by Scopus
Clarivate
Analytics
Formerly the IP & Science
business of Thomson Reuters

Logo



eISSN: 2329-0358

Get your full text copy in PDF

The Biocompatibility of Nitrided Titanium Alloy for Bone Implantation Studied by Laser Flow Cytometry, Laser Scanning Cytometry and Confocal Microscopy

E Czarnowska, A Sowinska, B Cukrowska, M Godlewski, T Wierzchon

Ann Transplant 2004; 9(1A): 72-75

ID: 15639


Objectives: Cell adhesion is a fundamental process influencing cell growth and dispersal, and can be studied by different methods.
Methods: The aim of our study was to evaluate the ability of human fibroblasts and osteoblasts to adhere to samples with nitrided surface layers produced under glow discharge conditions on titanium alloy using laser flow cytometry (FC), laser scanning cytometry (LSC) and confocal microscopy (CM). The expression of fibronectin and its receptor – α5β1 integrin (the CD49e molecule) was analyzed.
Results and Conclusions: Our results showed that fibroblasts and osteoblast-like cells (Saos-2 cell lines) adhere to a TiN+Ti2N+αTi(N) surface layer, which favours its application in bone surgery. Employment of LSC together with CM for analysis of cell behavior in contact with biomaterials seems to be very useful, while FC analysis of chemically harvested cells should be carefully taken into account in the study of cell adhesion processes.

This paper has been published under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially.