01 January 2009
Pulmonary artery stenosis shortly after lung transplantation: Successful balloon dilation and stent insertion in one case
Katayoun Najafizadeh, Abolghasem Daneshvar, Azizollah Abbasi Dezfouli, Babak Sharif Kashani, Zargham Hossein Ahmadi, Mohammad Behgam Shadmehr, Masoud Ghasemi, Babak Kardavani, Maryam Moghani Lankarani, Shadi ShafaghiAnn Transplant 2009; 14(1): 52-55 :: ID: 880231
Abstract
Background: Pulmonary artery stenosis after lung transplantation is a rare complication. It usually requires surgical correction but even after that the outcome is not favorable.
Case Report: The patient was a 53-years-old woman who was candidate for lung transplantation surgery due to pulmonary fibrosis. After 7 months on waiting list, with severe limitations in daily living activities, she received a single lung transplant in 2007. The surgery was performed without any complication. One day after surgery and after extubation, the patient needed oxygen supplementation through mask with reservoir bag. In bronchoscopy, black-and-white exudate and black membrane that blocked the main bronchus in the transplanted lung was observed. By bronchial lavage the membrane and exudate were successfully removed and patient received antibiotics for documented Aspergillus infection and Methylprednisolone pulse therapy for evidences of graft rejection. Despite success in treatments of the mentioned complications, the condition of the patient deteriorated and she became totally dependent to supplemental oxygen. Oxygen consumption level had increase and pulmonary artery pressure was increasing gradually. With suspicion to pulmonary artery stenosis, bronchial CT-Scan with contrast was performed 13 days after transplantation surgery which showed a 50% stenosis. Trans-esophageal echocardiography also showed a stenosis with 40 mmHg gradient. 18 days after transplantation surgery, percutaneous balloon angioplasty was performed which was initially successful but re-stenosis occurred. Seven days later, another balloon angioplasty with stent insertion was performed. After the procedure, the gradient has been removed. Patient was discharged 30 days after transplantation. Follow-up after 10 months revealed not stenosis and the stent was working properly.
Conclusions: Stent angioplasty can be performed with no problem or complication if pulmonary artery stenosis is seen after lung transplantation.
Keywords: Lung Transplantation, nulliparous women, Pulmonary Artery
In Press
Original article
A New Routine Immunity Score (RIS2020) to Predict Severe Infection in Solid-Organ Transplant RecipientsAnn Transplant In Press; DOI: 10.12659/AOT.946233
Original article
Survival Analysis of Liver Transplants in Patients with Acute Liver Failure from Acetaminophen and Mushroom...Ann Transplant In Press; DOI: 10.12659/AOT.946485
Original article
Medication Adherence Among Pediatric Post-Heart Transplant Patients in a Tertiary Care HospitalAnn Transplant In Press; DOI: 10.12659/AOT.946905
Most Viewed Current Articles
03 Jan 2023 : Original article 6,368
Impact of Autologous Stem Cell Transplantation on Primary Central Nervous System Lymphoma in First-Line and...DOI :10.12659/AOT.938467
Ann Transplant 2023; 28:e938467
16 May 2023 : Original article 6,030
Breaking Antimicrobial Resistance: High-Dose Amoxicillin with Clavulanic Acid for Urinary Tract Infections ...DOI :10.12659/AOT.939258
Ann Transplant 2023; 28:e939258
15 Aug 2023 : Review article 5,906
Free-Circulating Nucleic Acids as Biomarkers in Patients After Solid Organ TransplantationDOI :10.12659/AOT.939750
Ann Transplant 2023; 28:e939750
17 Jan 2023 : Original article 5,150
Non-Cryopreserved Peripheral Blood Stem Cell Graft for Autologous Hematopoietic Stem Cell Transplantation i...DOI :10.12659/AOT.938595
Ann Transplant 2023; 28:e938595