31 March 2012
Right ventricular function during orthotopic liver transplantation: Three-dimensional transesophageal echocardiography and thermodilution
Christian RosendalABCDEF, Keneshbek Almamat UuluBCDEF, Raffaele De SimoneF, Ivo WolfCD, Andreas DeckertCD, Eike O. MartinDF, Bernd W. BöttigerDF, Helmut RauchABCDDOI: 10.12659/AOT.882632
Ann Transplant 2012; 17(1): 21-30
Abstract
Background: Right ventricular (RV) function is an important aspect of anesthesia management during orthotopic liver transplantation (OLT). Because of its geometrical complexity, assessment of RV dimensions with transesophageal echocardiography (TEE) is a difficult task. The aim of this prospective single-site study was to investigate the feasibility of intraoperative assessment of RV parameters based on reconstructive three-dimensional (3D) TEE and to compare the measurements to thermodilution-derived values acquired with a modified pulmonary artery catheter.
Material/Methods: Measurements were performed at four different time points during 30 OLT with 3D-TEE. At the same time comparative values of RV parameters were acquired with a fast-response thermistor pulmonary artery catheter.
Results: 3D reconstruction was feasible in all patients. RV dimensions measured with 3D-TEE averaged 119.4ml (±38.5 ml) for enddiastolic and 68.9 ml (±27.7 ml) for endsystolic volumes. The RV ejection fraction was 42.2% (±9.3%). The volumes obtained by thermodilution were 263.7 ml (±64.5 ml) enddiastolic and 159.3 ml (±47.5 ml) endsystolic, both significantly greater than by 3D-TEE, and the ejection fraction was found to be 39.5% (±8.4%). No correlation was found between the volumes or the function determined by either method.
Conclusions: Reconstructive 3D-TEE is a viable technique during OLT and leads to plausible RV parameters. However, no correlation was found with simultaneous measurements or parameters performed with thermodilution. However, based on our data cardiac output measurements by thermodilution appear reasonable. Due to both lack of agreement with 3D-TEE and extraordinary high RV volumes the question about the most valuable monitoring technique of RV dimensions and function during OLT can not finally be answered.
Keywords: Pulmonary artery catheter, transesophageal echocardiography, three-dimensional reconstruction, right ventricule, Orthotopic Liver Transplantation
In Press
Original article
Retrospective Study to Compare Outcomes in 159 Patients Undergoing First Autologous Stem Cell Transplantati...Ann Transplant In Press; DOI: 10.12659/AOT.947186
Case report
Pulmonary Embolism Following Living Donor Hepatectomy: A Report of 4 Cases and Literature ReviewAnn Transplant In Press; DOI: 10.12659/AOT.946752
Most Viewed Current Articles
03 Jan 2023 : Original article 6,513
Impact of Autologous Stem Cell Transplantation on Primary Central Nervous System Lymphoma in First-Line and...DOI :10.12659/AOT.938467
Ann Transplant 2023; 28:e938467
15 Aug 2023 : Review article 6,136
Free-Circulating Nucleic Acids as Biomarkers in Patients After Solid Organ TransplantationDOI :10.12659/AOT.939750
Ann Transplant 2023; 28:e939750
16 May 2023 : Original article 6,130
Breaking Antimicrobial Resistance: High-Dose Amoxicillin with Clavulanic Acid for Urinary Tract Infections ...DOI :10.12659/AOT.939258
Ann Transplant 2023; 28:e939258
17 Jan 2023 : Original article 5,257
Non-Cryopreserved Peripheral Blood Stem Cell Graft for Autologous Hematopoietic Stem Cell Transplantation i...DOI :10.12659/AOT.938595
Ann Transplant 2023; 28:e938595